The ZN63(VS1)-12P vacuum circuit breaker holds significant importance as a development product in the field of electric technology, and it is specifically designed for the application of medium voltage. Operating at a rated voltage of 12 kV and a frequency of 50 Hz, this circuit breaker is applicable indoors, thus finding its ideal position in industrial and mining enterprises, power plants, and substations. Its main function is to provide dependable control and protection for electrical installations, particularly where the operating conditions require numerous switching operations. The ZN63(VS1)-12P fulfils the requirements of the IEC 62271-100 standard. This largely helps in ensuring safety, while it also increases efficiency in the operation of the device.
Key Features of the ZN63(VS1)-12P
Design innovation is one unique selling point that sets ZN63(VS1)-12P apart. By default, the circuit breaker adopts a double spring integrated mechanism that increases efficiency in operations massively. This mechanism is important in terms of the assurance it gives that the circuit breaker can perform reliably in critical conditions.
I. Hermetically Sealed Design
High-quality epoxy resin insulation material hermetically seals the vacuum arc extinguishing chamber. The design should account for the susceptibility of chambers to environmental pollutants and moisture, ensuring product longevity and improving reliability. The vacuum integrity in the chamber is vital for arc extinction.
II. Energy Storage Mechanism
Another feature of this ZN63(VS1)-12P is that the spring stored energy design for its operating mechanism has also allowed both electric and manual energy storage functions, which are possible in the specification design. Efficiency in energy storage contributes to quicker operation times, hence faster responses during fault conditions. This feature provides an advantage in industrial settings where losses occasioned by downtime can be immense.
III. Advanced Buffer Device
The advanced buffer device minimized the rebound during disconnection in the circuit breaker. This reduces impacts and vibration to allow smoother operation with fewer mechanical wear and tear effects over a period. The buffer gives extra protection to users, ensuring that at no time will disconnections cause sudden jolts or jerky movements that may cause accidents affecting personnel and equipment.
IV. No Maintenance Required
Perhaps one of the most attractive features of the ZN63(VS1)-12P series has to be maintenance-free operation. With such high reliability and excellent consistency within the products, the users would anticipate less intervention within the lifetime of a device. As a matter of fact, the 20,000 operations in mechanical lifespan for operation of a circuit breaker are achievable, thus making it highly cost-effective for companies that seek to minimize their overall costs of maintenance while maximizing the time of operation.
Operating Conditions
The following are the conditions that must prevail to realize full performance of ZN63(VS1)-12P:
a) Temperature Range
The circuit breaker operates effectively within the temperature range of -15°C to +40°C. It may withstand -30°C for storage and transportation purposes. This makes it suitable for a wide variation of geographical locations and climates.
b) Altitude Limitations
It can operate well within an altitude of 1000 meters with no deterioration in its performance. Therefore, this capability of withstanding altitude allows its deployment to vary from coastal to mountainous regions.
c) Humidity Considerations
The level of humidity is an important aspect when dealing with electrical equipment. The daily average relative humidity handled by the ZN63(VS1)-12P does not exceed 95% while the monthly average does not go over 90%. This will further provide the necessary conditions to ensure water vapor will not affect the performance of the circuit breaker.
d) Seismic Resistance
To ensure additional safety, the engineers have engineered the ZN63(VS1)-12P to withstand seismic activity up to 8 degrees on the Richter scale in seismically active regions. This ensures additional reliability, and ensures that the circuit breaker will function during earthquakes.
e) Environmental Restrictions
To provide a guarantee of safety, it is necessary to use this circuit breaker in places without fire dangers, serious pollution, chemical corrosion, and violent vibration. Only then can these restrictions provide a guarantee of the integrity of this device during long periods of time.
Compliance with the IEC Standards
IEC 62271-100 provides very essential requirements on AC circuit breakers that are intended to use in high voltage systems. Compliance with this standard at the time of manufacturing will ensure that the ZN63(VS1)-12P passes certain critical benchmarks touching on safety and performance, to wit:
- Dielectric Properties: The IEC standards deal with critical areas of dielectric properties. On the ZN63(VS1) -12P extensive work has been done to ensure good insulation during operation and, thereby reduce the incidence of electrical faults.
- Temperature Rise Testing: Temperature rise testing describes the performance of electrical equipment to perform efficiently under load conditions without overheating. The temperature rise testing on the ZN63(VS1)-12P was successful, confirming that it can withstand long operating conditions without any deterioration of properties.
- Mechanical Durability Tests: The mechanical durability tests make it possible to find out how long a device could work without maintenance or replacement. Some extensive mechanical testing was carried out on the ZN63(VS1)-12P to confirm its service life up to 20,000 operations with no substantial wear or failure.
Applications of the ZN63(VS1)-12P
The versatility of the ZN63(VS1)-12P makes it suitable for many applications:
Industrial Facilities
Electrical protection in industry should be reliable. The ZN63(VS1)-12P provides the indispensable control mechanisms to avoid overloading or short circuiting that can cause further damage to the equipment. Quick responses are very important in minimizing the downtimes along production lines.
Mining Operations
Mining operations are very often conducted in harsh environments where the reliability of equipment is foremost in mind. Because the ZN63(VS1)-12P design has a hermetically sealed construction, it most definitely will withstand the dust and moisture associated with such environments.
Power Plants and Substations
The power plants and substations demand powerful electrical management systems, which must bear the high load without compromising on the standards of safety. In that respect, ZN63(VS1)-12P serves the two important roles of effective electrical distribution management along with fault protections.
Conclusion: Why Choose ZN63(VS1)-12P?
In all, ZN63(VS1)-12P vacuum circuit breaker is one of the best options for medium voltage in different industries. New design features like hermetically sealed, energy-saving operating mechanism, and novelty buffer device assure the product to be more reliable in business investment and raise the level of safety and effectiveness of electrical systems. By guaranteeing the attainment of all international standards, such as IEC 62271-100, users can be assured that they are investing in a product that meets high safety standards while providing superior performance over its lifecycle. From industrial facilities and mining operations to power plants, this is a circuit breaker with unparalleled reliability and operational efficiency.
For purchase inquiries or integration of the ZN63(VS1)-12P vacuum circuit breaker into your electrical systems, please contact CNC Electric at cncele@cncele.com. The investment in this quality of technology surely pays for itself in improved safety and lower operational costs over time.
Media Contact
Company Name: CNC ELECTRIC GROUP CO.,LTD.
Email: Send Email
Phone: 86-577-61989999
Address:CNC High-Tech Hutou Industrial Zone, Liushi Town
City: Yueqing
State: Wenzhou
Country: China
Website: https://www.cncele.com/